CT Imaging in Practice: A Clinical Scenario

Computed Tomography (CT) is one of the most widely used imaging modalities in modern medicine. It combines X-ray technology with advanced computer processing to generate detailed cross-sectional images of the body. CT plays a central role in diagnosing trauma, cancer, cardiovascular disease, and neurological disorders.

This training scenario follows a patient referred for CT imaging at a large teaching hospital. By stepping through the imaging process and associated concepts, you will see how fundamental principles of CTโ€”including attenuation, reconstruction, windowing, pitch, dose management, and contrast useโ€”come together in clinical practice.

At the end of this scenario, you will complete a knowledge check quiz. The questions are directly linked to the information presented here, so pay close attention to the details as you progress.

Scenario: Sarahโ€™s CT Examination

Referral for imaging

Sarah, a 52-year-old woman, presented at the emergency department with acute abdominal pain. After initial assessment, the clinician requested an abdominal CT scan to rule out causes such as appendicitis, perforation, or bowel obstruction. This is a common indication for CT imaging, since the technique can rapidly visualise internal organs, vascular structures, and free air.

The CT scanner environment

Sarah was taken to the radiology department. The radiographer explained that she would be positioned on the patient table, which would pass through the CT gantry. The gantry houses the X-ray tube, detectors, and the rotating mechanical system required to generate the images.

As the table moved into position, the radiographer reassured her that the scan would be painless but involved exposure to ionising radiationโ€”a typical risk of CT.

Axial imaging and display

The scan was performed in axial mode, where images are acquired as cross-sections perpendicular to the patientโ€™s long axis. These axial slices were then reconstructed and displayed on the workstation. Radiologists typically review CT images in axial format, although multiplanar reformats (MPRs) and 3D renderings are also possible.

Tissue Attenuation and Hounsfield Units

On the workstation, the radiographer reviewed images measured in Hounsfield Units (HU)โ€”the scale used to quantify tissue attenuation in CT. Water has a HU value of 0, and all other tissues are measured relative to this. For example:

  • Lung tissue typically measures around -800 to -900 HU.
  • Fat measures around -100 HU.
  • Soft tissues such as liver or muscle measure around +40 HU.
  • Bone can measure above +1000 HU, making it appear brightest on the scan.

This standardised scale allows radiologists to distinguish between different tissues.

Windowing in CT

The radiologist adjusted the window width and window level on the images. Windowing controls the contrast and brightness applied to CT images, enabling optimal visualisation of different tissues. A narrow window is used for soft tissues, while a wide window is applied for lung or bone to prevent saturation of the bright or dark areas.

Use of contrast media

For Sarahโ€™s case, the radiologist required intravenous iodinated contrast media, the most common type used in CT. Contrast improves visualisation of vascular structures and enhances differentiation between normal and abnormal tissue. For example, contrast can highlight a perforated bowel or detect abnormal vascular patterns. Without contrast, some pathologies would be difficult to identify.

Multislice CT

The scanner used was a 64-slice multislice CT system. Multislice CT refers to scanners with multiple rows of detectors, allowing acquisition of many slices in a single rotation. This enables faster scanning, improved spatial resolution, and reduced motion artefacts, which is particularly useful in abdominal and cardiac imaging.

Helical scanning and pitch

During Sarahโ€™s examination, the table moved continuously as the gantry rotated, performing a helical CT scan. In this mode, the concept of pitch becomes important. Pitch is the ratio of table movement per gantry rotation to the beam width. A higher pitch means faster scanning and potentially lower dose, but with some loss of image resolution. A lower pitch provides higher resolution but increases dose and scan time.

Image reconstruction

The acquired raw data were processed using iterative reconstruction algorithms. Iterative reconstruction reduces image noise and improves quality compared with traditional filtered back projection, especially at lower radiation doses. This allows the department to achieve diagnostic-quality images while keeping patient dose as low as reasonably achievable (ALARA).

Beam hardening artefacts

As the radiologist scrolled through the images, they noted mild streak artefacts adjacent to dense bony structures. This was explained by beam hardeningโ€”an artefact caused when lower-energy X-ray photons are absorbed more readily as the beam passes through dense material such as bone, leaving the beam โ€œharderโ€ (with higher average energy). Corrections in software help reduce this effect, but it remains a familiar artefact in CT imaging.

Dose considerations and radiosensitive organs

Although CT is invaluable for diagnosis, it involves higher doses than conventional radiography. In abdominal CT, the radiosensitive organs of concern include the ovaries in women and the testes in men. In general, the most radiosensitive organ in CT is the thyroid gland, though breast and gonadal tissues are also highly sensitive. Dose optimisation techniques such as automatic tube current modulation, shielding, and iterative reconstruction all contribute to reducing unnecessary exposure.

Final diagnosis

The radiologist completed the review of Sarahโ€™s images. The contrast-enhanced CT clearly demonstrated an inflamed appendix with peri-appendiceal fat stranding, consistent with acute appendicitis. Thanks to rapid imaging, Sarah was able to proceed quickly to surgery with confidence in the diagnosis.

Key Concepts Illustrated

Through Sarahโ€™s CT examination, several fundamental concepts were demonstrated:

  • CT stands for Computed Tomography, a cross-sectional imaging technique using X-rays.
  • Images are measured in Hounsfield Units, with water at 0 HU.
  • Axial slices are the standard format of CT display.
  • Windowing controls image contrast and brightness.
  • Iodinated contrast media enhance vascular and tissue visibility.
  • Bone appears brightest due to high attenuation.
  • Multislice CT enables faster acquisition and improved resolution.
  • Helical pitch influences scan speed, resolution, and dose.
  • Iterative reconstruction improves image quality while lowering dose.
  • Beam hardening is a common artefact caused by dense structures.
  • The thyroid is among the most radiosensitive organs in CT.
  • Radiation exposure remains a risk, so dose optimisation is essential.

Conclusion

This clinical scenario demonstrates how CT combines technology, physics, and clinical application to provide rapid, detailed imaging of the body. By understanding principles such as attenuation, windowing, contrast use, pitch, and reconstruction, radiographers and radiologists can optimise image quality while minimising patient risk.

Knowledge Check

You have now reviewed the essential principles of CT imaging through a practical clinical case. The following knowledge check quiz is designed to test your understanding of the key topics introduced in this scenario, including image reconstruction, beam hardening, windowing, contrast media, attenuation values, and dose considerations.

Instruction: Select the best answer from the options provided. Refer back to the scenario if needed, and use it to guide your responses. Completing the quiz will help you consolidate your knowledge and ensure you are confident in applying these CT concepts to clinical practice.

Computed Tomography Quiz

Computed tomography uses X-rays and computer processing to produce detailed cross-sectional images of internal body structures.

1 / 20

Which of the following best describes iterative reconstruction?

2 / 20

What is beam hardening in CT imaging?

3 / 20

How are axial CT images typically displayed?

4 / 20

Which organ is most radiosensitive in CT scans?

5 / 20

What does "windowing" in CT imaging affect?

6 / 20

Which is a typical risk associated with CT imaging?

7 / 20

What does "multislice CT" refer to?

8 / 20

What is a common indication for a CT head scan?

9 / 20

What type of contrast media is commonly used in CT imaging?

10 / 20

Which material appears brightest on a CT scan?

11 / 20

In CT, why is contrast media often used?

12 / 20

What is "pitch" in helical CT?

13 / 20

Which of the following can reduce patient dose in CT scanning?

14 / 20

Which organ would typically have a Hounsfield Unit close to -1000?

15 / 20

What is the Hounsfield Unit of water?

16 / 20

Which unit is used to measure tissue attenuation in CT?

17 / 20

In CT, what is the purpose of the detector array?

18 / 20

What is the function of the CT gantry?

19 / 20

Which of the following best describes how CT imaging works?

20 / 20

What does CT stand for in medical imaging?

Your score is

The average score is 0%

Disclaimer
This clinical scenario is provided for educational and training purposes only. It is a fictional case study designed to illustrate the principles and practical applications of Computed Tomography (CT) imaging in a clinical setting. The information should not be interpreted as medical advice or used as a substitute for professional diagnosis, treatment, or patient care. Healthcare professionals should always rely on their clinical judgement, institutional protocols, and current guidelines when making decisions about imaging or treatment. Any resemblance to actual persons, living or deceased, is purely coincidental.

You are here: home ยป CT imaging in clinical practice